Thiết bị chứa khí LNG
Liquefield Nature Gas Cylinders For Vehicles(Factory Price)
Model | NorminalVolume L | ValidVolume L | Diametermm | Length mm | Net Weightkg | Filling Weight(LNG) kg | Evaporate Rate(LIN)%/day |
CDPW-500 | 500 | 460 | 666 | 2195 | 307 | 191 | 2.0 |
CDPW-450 | 450 | 414 | 666 | 1990 | 287 | 173 | 2.1 |
CDPW-380 | 380 | 342 | 666 | 1770 | 258 | 146 | 2.146 |
CDPW-365 | 365 | 328 | 618 | 1912 | 242 | 135 | 2.166 |
CDPW-330 | 330 | 303 | 618 | 1795 | 220 | 127 | 2.18 |
CDPW-275 | 275 | 253 | 618 | 1595 | 193 | 106 | 2.225 |
CDPW-245 | 245 | 225 | 566 | 1587 | 169 | 94 | 2.255 |
CDPW-200 | 200 | 184 | 566 | 1382 | 151 | 77 | 2.3 |
CDPW-180 | 180 | 165 | 566 | 1277 | 142 | 69 | 2.38 |
CDPW-150 | 150 | 138 | 566 | 1127 | 130 | 58 | 2.9 |

THÔNG TIN HỮU ÍCH
1. Industrial Gas Cryogenic Cylinder
Specification: 175L/195L/210L/480/500/785 and other non-standard
Medium: LOX/LAR/LIN
Working pressure: 1.4Mpa/1.6Mpa/2.0Mpa/3.5Mpa
Insulating mode: Super Vacuum Multi-Layer
This is applied to store, transport the liquefied gas for scientific research , chemical, electronic industries. We use unique technology to control whole production process under the strict quality guaranty system.
2.LNG Welded Cylinder
Specification: 175L/195L/210L/410L and other non-standard
Medium: LNG
Working pressure: ≤1.6Mpa
Insulating mode: Super Vacuum Multi-Layer
It applies to store and transport LNG in supply chain.
Mode | DP-175/1.4 | DP-175/2.0 | DP-195/1.4 | DP-195/2.0 | DP-210/1.4 | DP-210/2.0 | DP-210/3.5 | DPW410/1.6 | DPW480/1.6 | DPW500/1.6 | DPW480/3.5 | DPW785/1.2 | |
Size mm | 506×1485 | 506×1485 | 506×1620 | 506×1620 | 506×1725 | 506×1725 | 506×1725 | 666×938×2105 | 706×1011×2130 | 756×1001×2198 | 706×1011×2130 | 706×1011×2130 | |
(Dia×Ht) | |||||||||||||
Weight Kg | ≈111 | ≈125 | ≈116 | ≈132 | ≈125 | ≈141 | ≈186 | ≈328 | ≈382 | ≈393 | ≈526 | ≈745 | |
Working pressure MPa | 1.4 | 2 | 1.4 | 2 | 1.4 | 2 | 3.5 | 1.6 | 1.6 | 1.6 | 3.5 | 1.2 | |
Safety valve open pressure MPa | 1.6 | 2.4 | 1.6 | 2.4 | 1.6 | 2.4 | 4.2/6.3 | 1.92/2.4 | 1.92/2.4 | 1.92/2.4 | 4.2/6.3 | 1.26/1.39 | |
Rupture disc pressure MPa | 2.6 | 3.6 | 2.6 | 3.6 | 2.6 | 3.6 | 6.3 | / | 2.88 | 2.88 | 6.3 | 1.39 | |
G.vol L | 175 | 175 | 195 | 195 | 210 | 210 | 210 | 410 | 480 | 500 | 480 | 785 | |
E.vol L | 160 | 160 | 180 | 180 | 195 | 195 | 195 | 369 | 432 | 450 | 432 | 746 | |
Max loading KG | LOX | 177 | 173 | 197 | 197 | 214 | 214 | 181 | / | 413 | 490 | 413 | 713 |
LAR | 217 | 212 | 241 | 241 | 261 | 261 | 218 | / | 499 | 575 | 499 | 861 | |
LIN | 126 | 123 | 140 | 140 | 152 | 152 | 116 | / | 264 | 340 | 264 | 455 | |
LNG | 66 | / | 73 | / | 82 | / | / | 157 | / | / | / | / | |
Air transfer rate | In a row:9.2M3/h, incontinuity :40M3/h(in 5 minutes) (also could be liquid outlet directly) | ||||||||||||
Level gauge type | Buoy type | Digital type | |||||||||||
Surface | Polishing |